spacer





Interior Mounted Vertical Lift Door
  Vertical Lift Door Dimension Selection Table #2
  Panel Thickness and Other Door Dimensions

 

Step 2:
Using Table #2, determine the panel thickness and other dimensions for your application based on the desired clear opening width.

 
Interior Elevation & Section Drawing
 

 
TABLE # 2

* The panel thickness indicated in this table is for estimating purposes only. It is based on average panel heights with a wind pressure of 20 pounds per square foot. Please consult the EPD factory for the exact panel thickness and other dimensions for your project.

 
       

Depth of Track & Tower
from Mounting Surface "C"

Door
Clear
Opening
Width

Panel
Thickness
Based on
20 PSF
Load "A"

Offset of
Track &
Tower to
Opening
Jamb "B"

Width of
Counter-
Weight
Tower
"G"

Single
Panel
Door
"C"

Two
Panel
Door
"C"

Three
Panel
Door
"C"

Four
Panel
Door
"C"

0' to 18'

4 inches *

2-1/2"

16"

12"

12"

16"

22"

19' to 22'

5 inches *

2-1/2"

16"

12"

14"

19"

26"

23' to 26'

6 inches *

2-1/2"

16"

12"

17"

24-1/2"

32"

27' to 38'

8 inches *

3-1/2"

16"

12"

21"

30-1/2"

40"

               

 

NOTE that the overall width "F" is equal to:
20" plus the clear opening width

   
   
   
Exterior Elevation Drawing